The key steps of fabricating devices for carbon-based nanoelectronics are:
To learn more about microfabrication processes look at http://en.wikipedia.org/wiki/Photolithography. The most important source of information is always the photoresist manufacture's data sheet (see the T: drive, Group documents\Photoresist documentation). There are also some good textbooks in the OSU library that cover all aspects of microfabrication:
For some philosophy on how to make a good recipe you might enjoy reading the zen of device making.
All experimental physicists working in this field have to learn best practices for handling chips.
Uses chrome masks to expose photoresist. See Photolithography
CAD software is used to design and export the patterns needed for photolithography. In some cases you will need to export .dxf files, in other case .gds files. Josh uses AuotoCAD, this is powerful, industry standard software which is free for academic users. Ethan used DesignCAD (2D version) when he worked in Delft. Matt and Landon like to use Layout Editor which is free, open source software.
Chrome masks are patterned using the direct write lithography system on campus. Chrome masks allow us to reach the 2 micron resolution limit of the contact aligner. There are two write lenses (labeled 10 mm and 2 mm), with a 2 µm or 0.5 µm spot size respectively. For the 2 µm spot size, a mask can be exposed at a rate of 1 square inch every 20 minutes regardless of the amount of exposed area. Using the 0.5 um spot size the write time is on the order of 1 square inch every 1.5 hrs. The write times are fairly insensitive to the complexity of the pattern data. However, large arrays of repetitive shapes can take up to 5 times longer to expose than normally expected.
There is an OSU Cleanroom wiki describing operating procedures for the DWL.
DWL Costs | |
---|---|
Laser time | $9/hour |
Mask blank | $20 |
developer/etchant/stripper | $26 |
Before the DWL was installed on campus we had to send CAD drawings to a mask making company. Commerically produced chrome masks cost $400 - 800 each.
Image of a chrome mask made with the DWL 2 µm spot size. The pink is chrome, the grey is transparent. More mask images. |
For less demanding resolution, for example 10-20 micron minimum feature size, a printed transparency can be used. These masks cost about $60 each and are purchased from a company in Bandon. Now we prefer to make chrome masks in the DWL.
Some tips for a successful mask design:
Matt and Ethan have used the ebeam system at CAMCOR (University of Oregon, 50 minute drive). A basic recipe is available.
In September 2011 the new ebeam lithography system was installed in the OSU Electron Microscopy Facility. Doug Kezsler's group, and Inpria are currently the expert users.
The initial photolithography steps are done on 3“ wafers. To grow nanotubes, however, we have to cleave the Si [1 0 0] wafer or ST-cut quartz into smaller pieces that will fit in our furnace. Matt is the expert when it comes to cleaving.
The only way to get truly square quartz pieces is to use a wafer dicing saw. There is one available in the OSU Cleanroom.
After doing photolithography, a thin layer of metal (tens of nanometers thick) is deposited on a nanotube chip. The interface between nanotube and metal is critical for device operation (for example, we do not store the chip in a gelpak before evaporation. This will lead to hydrocarbon contamination).
Our workhorse deposition system is the thermal evaporator in Janet Tate's lab, 4th floor Weniger Hall. We have used this system for chrome, gold, aluminum, and iron. Please see Matt Leyden for training. Always follow the standard operating procedure in a step by step fashion - missing one step can ruin your sample and the equipment. Matt and Josh renovated this evaporator in summer 2008.
Evaporation boats are made Tungstun and cost $6-8 each (R. D. Mathis). The boats should be kept clean and reused when possible.
Thin film deposition is monitored by a quartz crystal microbalance (QCM). The operator enters the density of the metal, the z-ratio of the metal and the tooling factor of the evaporator. Density and z-ratio can be looked up on a table. The tooling factor is a geometric factor, basically the ratio of the distance between source and QCM and the distance between the source and sample. When the QCM readings do not agree with AFM characterization of film thickness, users typically adjust the tooling factor.
For thermal evaporation, metal is usually held in a boat made out of Tungsten (W) because the melting point of W is 3422 °C. It is possible to break the boat by heating or cooling too fast. It is also bad for the sample if the temperature inside the evaporator gets too hot.
This evaporation table gives useful advice about which metals can be thermally evaporated. Similar information is on the Kurt Lesker website. For example,
The clean room in Kelley has a new ebeam deposition system. Metals like iron & palladium which are difficult to evaporate thermally can be deposited with the ebeam system. Ask Josh Kevek for more information.
Sputtering is an alternative to thermal evaporation that we have not yet explored. The deposition rate should be more stable. Milo Koretski has a beautiful new sputtering system set up in the chemical engineering department which he used for CNT catalyst deposition.
John Wager's group has an ebeam evaporator. E-beam evaporation is especially useful for metals that are hard to control or hard to melt, like iron and molybdenum.
When making devices from aligned CNTs the unused tubes need to be etched. We currently use the O2 plasma in the Owen Hall clean room. This O2 plasma removes photoresist at a rate of about 100 nm/minute. The recipe from Rogers Nature Nanotech 2007 is 50 mTorr, 20 sccm O2, 30 W, 30 s.
More oxygen plasma details.
See here for the procedure to do this in our e-beam system. Annealing some kinds of nanotube devices in vacuum seems to decrease contact resistance, improve a leaky gate oxide, and remove surface contaminants. Starting in the ~0.01 mTorr range increase the temperature in increments of 100 C. When you get to 600 C, turn off the heater and allow the device to cool in vacuum to ~200 C before venting. So far, results suggest this improves resistances by ~80%. See the Phil Collin's paper for more information.
User fees (March 2010)
(I) On SiO2 substrate (0) -Expose alignment marks on wafer (see: Photolithography Procedures). -Deposit Chromium using E-beam procedures (about 30 nm). -Place sample in PG-remover on hotplate at 65 C to remove photochemicals and excess metal. Leave for about 15 minutes. Using pipette to gently remove as much metal as possible while in solution. Transfer to fresh PG bath on hotplate. Leave overnight. Rinse with IPA and DI water, then dry with N2 to store. (1) Add prepared graphene to chip. (see Preparation of Graphene). Let dry overnight in covered dish. Soak in acetone overnight to remove PMMA. Rinse with IPA and DI water, dry with N2. (2) Spin-coat chip, expose device contacts using photolithography and develop (see: Photolithography Procedures). (3) Dep. Cr or Ti (1 nm) and Au (50 nm) using E-beam. (4) Place sample in PG-remover on hotplate at 60 C to remove photochemicals and excess metal. Leave for about 15 minutes. Using pipette to gently remove as much metal as possible while in solution. Transfer to fresh PG bath on hotplate. Leave overnight. Rinse with IPA and DI water, then dry with N2 to store. (5) Spin-coat chip, expose graphene using photolithography and develop (see: Photolithography Procedures). (6) Plasma-etch to remove excess graphene (see: Plasma Etch Procedures) (7) [optional: to isolate leads] Dep. SiO2 (50-100 nm) everywhere apart from contact regions. Place in PG-remover, following same procedure as for metal deposition.
(II) On glass cover slip (0) [optional: for releasable devices] Use chip with AlO3 already deposited. (1) Add prepared graphene to cover slip. (see: Preparation of Graphene). Let dry overnight in covered dish. Soak in acetone overnight to remove PMMA. Rinse with IPA and DI water, dry with N2. (2) Expose device contacts using lithography and develop (see: Photolithography Procedures). (3) Deposit Cr or Ti (1 nm) and Au (50 nm) using E-beam. (4) Place sample in PG-remover on hotplate at 60 C to remove photochemicals and excess metal. Leave for about 15 minutes. Using pipette to gently remove as much metal as possible while in solution. Transfer to fresh PG bath. Leave overnight. Rinse with IPA and DI water, then dry with N2 to store. (5) Expose graphene using photolithography and develop (see: Photolithography Procedures). (6) Plasma-etch to remove excess graphene (see: Plasma Etch Procedures).
(1) Cut graphene on copper (Cu) foil to desired size (the side with the graphene on it should be marked). (2) [Oksana’s lab] Spin PMMA (use 2% PMMA in anisole) onto graphene side. a. Turn on air and lights in fume hood; sign in for instrument use. b. Set spin coater to 3000 rpm for 60 s. Use chuck with small holes in top (not o-ring). c. Set Cu sample on chuck, with graphene side facing up, ensuring all holes are covered. Put chuck onto spin coater. d. Open PMMA in fume hood. Cleanly pipette several drops onto graphene. Press “vacuum”; close lid and begin spin coat. e. Carefully remove coated sample and store. (3) [Ethan’s lab] Hard-bake @ 90 C for 60 s. (4) Float in CE200, copper-side down, for about 8 hours. (5) Remove from solution using tongs and plate, and put into water bath (“water PMMA” label) for about 15 minutes. (6) Transfer to fresh DI water bath. Leave for at least 15 minutes (longer is acceptable). Repeat twice more. (7) Store graphene floating in water bath. (now the graphene still has a layer of PMMA on it ⇒ once graphene has dried overnight on substrate, remove PMMA by soaking in acetone overnight, followed with IPA and H2O rinse).
(last edit: 1/2/18 by Carly) (1) Place samples inside chamber. (2) Turn on plama-etcher (switch on back). (3) Press twice (starts power) (4) Toggle left or right to Setup menu, press Use settings: a. Vacuum set point 201.1 b. Atmospheric Vent 00:15 c. Purge Vent 00 d. Gas Stabilize 59 e. Vacuum Alarm 5:00 minutes Important! If the vacuum is not reached by this time limit, system shuts down. f. Plasma Time: 3:00 minutes (5) Press up to return to main menu. Select Commands. Select Plasma to begin process. (6) After timer runs out, go back to Commands menu, and select Off. (7) Remove samples from chamber.