 ===== SOP: PC Stamps and Transfers===== ===== SOP: PC Stamps and Transfers=====
 +==Author: Miller Nelson, Updated 11.12.2026 Sydney Pfleiger==
 ==Before you begin== ==Before you begin==
 PC/Chloroform solution should spin on a hot plate at room temperature for at least 4 hours leading up to use. Failure to adequately prepare can make the polymer hard to pipette and cure accurately. In a pinch, 5 minutes in the sonicator may help to reduce this spin time. PC/Chloroform solution should spin on a hot plate at room temperature for at least 4 hours leading up to use. Failure to adequately prepare can make the polymer hard to pipette and cure accurately. In a pinch, 5 minutes in the sonicator may help to reduce this spin time.
Line 282: Line 282:
  
  
-===== SOP: PCL Stamps ====+===== SOP: PCL Stamps ===== 
 +==Author: Miller Nelson, Updated 11.12.2026 Sydney Pfleiger==
 == 1. Before you begin...== == 1. Before you begin...==
 a. PCL should spin on the hot plate at room temperature in room 308 for 24 hours leading up to use. Failure to adequately prepare can make the polymer hard to pipette and cure accurately. a. PCL should spin on the hot plate at room temperature in room 308 for 24 hours leading up to use. Failure to adequately prepare can make the polymer hard to pipette and cure accurately.